Worcester Greenstar 28i Junior Boiler Repair in Healing
Appliance Details
- Job Type: Boiler Repair
- Manufacturer: Worcester
- Model: Greenstar 28i Junior
- GC Number: 47-311-87
Findings & Diagnostics
Reported/Observed Symptom:
Customer reported their Worcester Greenstar Junior boiler (GC number: 47-311-87) wasn't igniting for heating or hot water.
Fault Code: Slow Flashing Blue Light & Flashing Lockout Reset Button
Diagnosis/Notes:
When working on the Worcester Greenstar Junior, you're able to read the fault code by observing both the illumination sequence of lockout reset button and the main blue control panel light.
The main blue control panel light has 2 main fault code indicators; (1.) Fast Flash (illuminated and off equal time periods) / (2.) Slow Flash (off for longer, then a fast flash)
The lockout reset button illumination has 2 options; (1.) Off / (2.) Flashing.
This Worcester Junior 28i had a slow flashing blue Light coupled with a flashing lockout reset button. Looking through the service manual for our fault code gave us the following options to check:
▶ Gas present and at correct pressure?
▶ Gas valve
– Check that there is approximately 27V d.c. to each solenoid
– Check the resistance of each solenoid:
– Top solenoid = 380 Ω ± 10% (342 - 418 Ω)
– Bottom solenoid = 190 Ω ± 10% (171 - 209 Ω)
▶ Combustion CO2 level.
▶ Flue condition.
– Blocked flue?
▶ Blocked condensate pipe or frozen condensate.
▶ Gas valve adjustment.
▶ Ignition electrodes/harness/connections.
– Check for condition and resistance of leads (approximately 2100 Ω)
▶ Otherwise replace control board
This was an easy diagnosis, the condensate trap was blocked with crud washed out of the heat exchanger. The boiler hadn't been serviced in several years, and dust / flies / anything which floating into the boiler air intake alongside small aluminium oxide flakes from the heat exchanger itself, drip into the boilers condensate trap. Generally these components are cleaned on an annual boiler service, but this system had missed 8 years of maintenance.
When burning natural gas in oxygen, the boiler collects a steady flow of condensate water which can flood the heat exchanger, damaging seals and electrodes. On this job, we could easily identify the water stains down the Worcester Juniors "kebab" style heat exchanger.
We cleaned the system and got their boiler back operational same day, but advised we book their boiler in for a full strip down service, where we would clean the heat exchanger and replace the burner gasket / electrodes.
Resolution
- Outcome: Boiler is safe to use.
- Parts Replaced: Burner Gasket, Electrodes
Additional Comments
Total cost for us to diagnose and get their heating back on same day was only £80 (labour). Because the boiler was ~14 years old and it'd been 8 years since it's last service, we advised a full boiler strip service and clean. Various boiler parts are classified as "consumables" and should be replaced every few years, so we ordered a Worcester Junior service kit, replacing the main burner gasket and electrodes. Total boiler service price, including the service pack was £80 labour + £38 Worcester Jnr Service Pack = £118
⚠️ Hard Water & System Sludge Detected
This diagnostic indicates the presence of system debris or scale. To protect the boiler lifespan and restore heating efficiency, we recommend evaluating the system for a Magnacleanse or Chemical Flush.
Facing a similar issue? Call our Gas Safe engineers directly on 07825 121000 for a rapid response.